Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 113
Filtrar
1.
J Fr Ophtalmol ; 46(5): 536-551, 2023 May.
Artigo em Francês | MEDLINE | ID: mdl-37068974

RESUMO

INTRODUCTION: For many years, surgeons and anesthetists have recognized that stress can be present in their daily professional practice. The goal of this study was to identify tools for assessing stress and cognitive load in the operating room. MATERIAL AND METHODS: We conducted a literature review in the PubMed database of scientific articles published on the subject without date limit using the keywords anesthesia, surgery, surgeon, cognitive workload, definition, pathophysiology, physiological measurement, objective, subjective, stress. RESULTS: Nineteen articles were selected, focusing on cardiac surgery, gastrointestinal surgery, vascular surgery and urology. No publications concerning ophthalmology were found through the literature search. The means of measurement found were either subjective, such as questionnaires, or objective, such as the study of heart rate variability (HRV), reaction time, eye movements, electrical conductivity of the skin, biological markers and electroencephalogram. Of all these measurement tools, the NASA-TLX questionnaire, used in four articles, and the HRV study, used in eight articles, appear to be the most widely used and are strongly correlated with stress. CONCLUSION: The articles reviewed use only some of the available tools for assessment of stress and cognitive load. The main objective is to improve the quality of care and the quality of life of caregivers. It would be interesting to develop other methods to identify and better characterize the risk factors that increase stress and cognitive load.


Assuntos
Salas Cirúrgicas , Cirurgiões , Humanos , Qualidade de Vida , Cirurgiões/psicologia , Cognição , Anestesistas
3.
Eur J Vasc Endovasc Surg ; 56(1): 68-77, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29706260

RESUMO

OBJECTIVE/BACKGROUND: Laser in situ fenestration (LISF) is emerging as an immediately available alternative in the endovascular treatment of complex aortic aneurysm. However, its biomechanical features remain poorly understood. The aim of this study was to experimentally evaluate textile damage secondary to LISF and to compare LISF with mechanical in situ fenestration (MISF). METHODS: An in vitro study evaluated the damage created by LISF on endograft fabrics versus MISF using a needle. Five different models of commercially available aortic endografts were used (32 samples of polyethylene terephthalate and expanded polytetrafluoroethylene fabrics). Tensile strength tests were performed on the fabrics before and after in situ fenestration, to determine the loss of mechanical strength. Integral water permeability tests at the stent-fenestration interface evaluated the watertightness of junctions. Stability of the connection was assessed with a fatigue bench test flexing the branch on the fenestration. In a second step, an in vivo study evaluating LISF in sheep was conducted. RESULTS: Resulting holes had circular and cauterised edges following LISF, whereas fabric filaments were pushed aside after MISF. Tensile tests demonstrated a 34% and a 27% mechanical resistance loss after LISF (p = .004) and MISF (p = .001) compared with non-fenestrated samples. A non-significant global decrease of 7% in mechanical resistance was found following LISF compared with MISF (p = .520). Water permeability tests highlighted that leak rates were higher following LISF than with MISF with regard to multifilament specimens (p < .05). Fatigue tests induced modification of the morphology of fenestrations. The surface area of the fenestration was increased for all samples after 170,000 cycles. Regarding the in vivo study, 14 LISF were performed in 12 sheep with a technical success rate of 88%. CONCLUSION: This study demonstrates that both LISF and MISF create substantial damage to all available endograft fabrics. Until comparisons with reinforced fenestrations are performed, LISF and MISF should not be used outside investigational studies.


Assuntos
Aorta Abdominal/cirurgia , Aorta Torácica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Desenho de Prótese , Animais , Aorta Abdominal/patologia , Aorta Abdominal/fisiopatologia , Aorta Torácica/patologia , Aorta Torácica/fisiopatologia , Fenômenos Biomecânicos , Análise de Falha de Equipamento , Hemodinâmica , Humanos , Teste de Materiais , Modelos Animais , Permeabilidade , Polietilenotereftalatos , Politetrafluoretileno , Falha de Prótese , Carneiro Doméstico , Estresse Mecânico , Resistência à Tração
8.
Eur J Vasc Endovasc Surg ; 54(3): 378-386, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28716448

RESUMO

OBJECTIVE/BACKGROUND: The goal of the present study was to assess the aging phenomena on second-generation textile endoprostheses (EPs) through explant analysis and to establish a preliminary classification of observed defects and material damages. METHODS: From January 2011 to June 2016 110 second- and recent-generation EPs were collected as a part of a European collaborative retrieval program. The analysis focused on the first 41 consecutive commercial EPs collected between 2011 and 2014 and made from polyethylene terephthalate. Explants were submitted to a standardized evaluation protocol, which included data recording, eye-naked evaluation, cleaning of organic remnants, and structural analysis under numerical optical microscopy. Observations were reported using a classification based on 15 features evaluating the fabric, the stitches between the fabric and the stents, and the stents. The total surface area of the holes within the fabric was measured. RESULTS: EPs were implanted for thoracic and abdominal procedures in 12 and 29 cases, respectively. The mean ± SD duration of implantation was 34 ± 26 months (range 2 days-8 years). Sixty-four percent of the samples demonstrated at least one defect caused by compression damage potentially related to the insertion of the EP within the delivery system, which promoted holes and tears. Ninety-five percent of all EPs demonstrated at least one type of abrasion on the stitches. The degradation of the stitches and the number of ruptures increased with duration of implantation. Stent degradation was rare and consisted of corrosion and rupture. Cumulated holed surface area increased with time and was measured up to 13.5 mm2. CONCLUSION: Various aging-related phenomena on commercial textile EPs were identified and classified. Main damaging mechanisms were related to compression and abrasion leading to tears and holes in the fabric and rupture of stitches.


Assuntos
Implante de Prótese Vascular/instrumentação , Prótese Vascular , Remoção de Dispositivo , Procedimentos Endovasculares/instrumentação , Falha de Prótese , Stents , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Análise de Falha de Equipamento , Europa (Continente) , Humanos , Dados Preliminares , Avaliação de Programas e Projetos de Saúde , Desenho de Prótese , Fatores de Risco , Propriedades de Superfície , Fatores de Tempo , Resultado do Tratamento
15.
J Med Vasc ; 42(1): 29-38, 2017 Feb.
Artigo em Francês | MEDLINE | ID: mdl-27989659

RESUMO

Ischemia-reperfusion, which is characterized by deficient oxygen supply and subsequent restoration of blood flow, can cause irreversible damage to tissue. The vascular surgeon is daily faced with ischemia-reperfusion situations. Indeed, arterial clamping induces ischemia, followed by reperfusion when declamping. Mechanisms underlying ischemia-reperfusion injury are complex and multifactorial. Increases in cellular calcium and reactive oxygen species, initiated during ischemia and then amplified upon reperfusion are thought to be the main mediators of reperfusion injury. Mitochondrial dysfunction also plays an important role. Extensive research has focused on increasing skeletal muscle tolerance to ischemia-reperfusion injury, especially through the use of ischemic conditioning strategies. The purpose of this review is to focus on the cellular responses associated with ischemia-reperfusion, as well as to discuss the effects of ischemic conditioning strategies. This would help the vascular surgeon in daily practice, in order to try to improve surgical outcome in the setting of ischemia-reperfusion.


Assuntos
Complicações Intraoperatórias/prevenção & controle , Complicações Intraoperatórias/fisiopatologia , Músculo Esquelético/irrigação sanguínea , Traumatismo por Reperfusão/prevenção & controle , Traumatismo por Reperfusão/fisiopatologia , Procedimentos Cirúrgicos Vasculares , Humanos , Complicações Intraoperatórias/etiologia , Precondicionamento Isquêmico , Traumatismo por Reperfusão/etiologia
17.
Transplant Proc ; 48(8): 2615-2621, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27788791

RESUMO

BACKGROUND: Delayed graft function (DGF) is an early postoperative complication of kidney transplantation (KT) predisposing to acute rejection and lower graft survival. Intraoperative arterial hypotension and hypovolemia are associated with DGF. Central venous pressure (CVP) is used to estimate volemia but its reliability has been criticized. Pleth variability index (PVI) is a hemodynamic parameter predicting fluid responsiveness. The aim of this study was to examine the relationship between intraoperative PVI and CVP values and the occurrence of DGF. METHODS: This was a prospective, noninterventional, observational, single-center study. All consecutive patients with KT from deceased donors were included. Recipients received standard, CVP, and PVI monitoring. Intraoperative hemodynamic parameters were recorded from recipients at 5 time points during KT. RESULTS: Forty patients were enrolled. There was a poor correlation between PVI and CVP values (r2 = 0.003; P = .44). Immediate graft function and DGF patients had similar hemodynamic values during KT, with the exception of PVI values, which were significantly higher in the DGF group. In particular, a PVI >9% before unclamping of the renal artery was the only predictive parameter of DGF in our multivariate analysis (P = .02). CONCLUSIONS: This study suggests that PVI values >9% during KT are associated with the occurrence of DGF.


Assuntos
Função Retardada do Enxerto/etiologia , Transplante de Rim/efeitos adversos , Monitorização Intraoperatória/estatística & dados numéricos , Adulto , Pressão Venosa Central/fisiologia , Feminino , Hemodinâmica/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/métodos , Monitorização Fisiológica/métodos , Monitorização Fisiológica/estatística & dados numéricos , Pletismografia/métodos , Pletismografia/estatística & dados numéricos , Estudos Prospectivos , Reprodutibilidade dos Testes , Fatores de Risco
18.
J Mal Vasc ; 41(4): 260-71, 2016 Jul.
Artigo em Francês | MEDLINE | ID: mdl-27342640

RESUMO

Type B aortic dissections are serious diseases with a 60 to 80 % 5-year survival rate. Although typically managed with a medical treatment, surgery may be necessary in the acute/subacute or the chronic phase if significant complications are encountered. For these patients, CT angiography is the first-line imaging modality, used for indicating and preparing the surgical procedure as well as for follow-up. Physicians in charge of these patients should be familiar with the key reading points. Visceral malperfusion is the most common acute complication, while aneurysmal dilatation of the false lumen is the most common chronic complication, with surgical management generally indicated when the axial diameter of the aorta exceeds 55mm. Endovascular treatment tends to replace open surgery: it requires precise measurements and identification of the entry tear (contribution of 4D-MRA).


Assuntos
Aneurisma da Aorta Torácica/diagnóstico por imagem , Dissecção Aórtica/diagnóstico por imagem , Período Pré-Operatório , Idoso , Idoso de 80 Anos ou mais , Dissecção Aórtica/cirurgia , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Aortografia , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares , Feminino , Humanos , Angiografia por Ressonância Magnética , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...